Seismic Performance Experimental Study on Vertical Connection Joints of Modular Concrete Wall-Floor
CSTR:
Author:
Affiliation:

1.China Construction Third Engineering Bureau Group (Shenzhen) Co., Ltd.;2.Jiangchen Housing Manufacturing (Zhuhai Hengqin) Co., LTD.;3.上海结奕建筑科技有限公司;4.Sanda University

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    To explore the seismic performance of vertical connection joints in modular concrete wall-floor, this study designed and tested three types of joints: monolithic casting, grout anchor connections, and bolt connections under cyclic loading. The research systematically evaluated their failure processes, hysteresis behavior, energy dissipation capacity, and the degradation of stiffness and strength. The test results indicate that regardless of the connection type used, all specimens tended to fail through bending and demonstrated excellent seismic performance, meeting the seismic demands in practical engineering applications. The seismic performance of the vertical connection joints using grout anchor connections was nearly identical to that of the monolithic cast specimens, showing comparable strength, ductility, energy dissipation capacity, and stiffness. However, specimens with bolt connections had lower strength and stiffness than monolithic cast specimens, but exhibited better ductility and enhanced energy dissipation performance compared to those using grout anchor connections and monolithic casting.

    Reference
    Related
    Cited by
Get Citation
Related Videos

Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:December 11,2024
  • Revised:June 03,2025
  • Adopted:August 14,2025
  • Online: July 31,2026
  • Published:
Article QR Code